Περιγραφή
Inverter air conditioner Airwell, AWSI-HKD012-N11
Inverter air conditioner Airwell, AWSI-HKD024-N11
has a power of 3.5 kW. Air conditioning heats up without any problems at temperatures up to -15 ° C. This inverter air conditioner has a high energy efficiency class. And it has the “I Feel” function for precise room temperature control
Inverter air conditioner Airwell, AWSI-HKD012-N11, main features:
- Capacities from 2.7 to 6.25 kW
- Heating and cooling operation at -15 ° C
- High Energy Efficiency Class A ++
- Photocatalytic and antibacterial filter
- I Feel for precise room temperature control
Indoor unit | AWSI-HKD009-N11 | AWSI-HKD012-N11 | AWSI-HKD018-N11 | AWSI-HKD024-N11 | ||
Outdoor unit | AWAU-YKD009-H11 | AWAU-YKD012-H11 | AWAU-YKD018-H11 | AWAU-YKD024-H11 | ||
Rated power | Cooling | kW | 2.65 (1.2-3.3) | 3.54 (1.3-4.4) | 5.0 (1.8-6.1) | 6.8 (2.7-7.8) |
Heating | kW | 2.8 (0.85-3.7) | 3.5 (1.2-4.8) | 5.0 (1.4-6.7) | 7.5 (1.6-8.7) | |
Power Consumption | Cooling | kW | 0.775 | 1.095 | 1.544 | 2.41 |
Heating | kW | 0.72 | 0.94 | 1.35 | 2.34 | |
SEER / Energy class | Cooling | 6.9/A++ | 6.8/A++ | 6.5/A++ | 6.3/A++ | |
SCOP / Energy Class (Moderate Climate) | Heating | 4.0/A+ | 4.4/A+ | 4.2/A+ | 4.0/A+ | |
SCOP / Energy class (warm climate) | Heating | 5.1/A+++ | 5.3/A+++ | 5.1/A+++ | 5.1/A+++ | |
Pdesignc | Cooling | kW | 2.65 | 3.54 | 5.00 | 6.80 |
Pdesignh (Moderate Climate) | Heating | kW | 2.40 | 2.60 | 4.20 | 5.50 |
Pdesignh (warm climate) | Heating | kW | 2.80 | 3.20 | 4.60 | 6.70 |
Capacity at -10 ° C | Heating | kW | 2.7 | 3.0 | 4.1 | 6.2 |
Capacity at -15 ° C | Heating | kW | 2.40 | 2.50 | 3.60 | 5.50 |
Fan flow rate | indoor unit | m3/h | 230/320/380/430 | 310/390/430/480 | 360/460/540/610 | 650/820/890/960 |
outdoor unit | m3/h | 1900 | 2000 | 2100 | 2700 | |
Sound pressure at a distance of 1 m | indoor unit | db(A) | 22/31/35/38 | 23/29/32/36 | 23/29/33/36 | 31/37/40/43 |
outdoor unit | db(A) | 45 | 46 | 49 | 50 | |
Sound power | indoor unit | db(A) | 54 | 53 | 57 | 63 |
outdoor unit | db(A) | 60 | 62 | 65 | 68 | |
Drying | indoor unit | L/h | 1.0 | 1.2 | 1.7 | 2.4 |
Compressor type | outdoor unit | Rotary DC Inverter | ||||
Dimensions | indoor unit | mm | 715x250x188 | 800x275x188 | 940x275x205 | 1045x315x235 |
outdoor unit | mm | 770x300x555 | 800x333x554 | 800x333x554 | 845x363x702 | |
Overall dimensions with packaging | indoor unit | mm | 775x260x324 | 865x265x350 | 1015x350x265 | 1135x315x395 |
outdoor unit | mm | 900x345x585 | 920x390x615 | 920x390x615 | 965x395x755 | |
Weight (net / gross) | indoor unit | kg | 6.5 / 8.2 | 7.4 / 9.5 | 9.0 / 12.2 | 12.0 / 15.2 |
outdoor unit | kg | 26.6 / 29 | 29.1 / 31.9 | 37.8 / 40.5 | 48.4 / 51.6 | |
Power supply 1 ~ 230V | Cross section of the power cord | mm2 | 3×1.5 | 3×1.5 | 3×1.5 | 3×2.5 |
Amperage of fuse | A | 10 | 10 | 16 | 25 | |
Electrical connections | mm2 | 5×1.5 | 5×1.5 | 5×1.5 | 5×2.5 | |
Piping | Ø gas | inch | 3/8” | 3/8” | 1/2” | 5/8” |
Ø fluid | inch | 1/4” | 1/4” | 1/4” | 3/8” | |
Maximum length | m | 25 | 25 | 30 | 50 | |
Maximum displacement | m | 10 | 10 | 20 | 25 |